Design Calculations using ASME Section VIII Division 1 and Finite Element Analysis (FEA) for Purge Head Reactor

Posted on 9:17 pm

Code calculations were performed using ASME Section VIII, Division 1 to determine the code compliance of a purge head reactor with internal diameter of 85” and internal pressure of 150 psig. Local stress calculations for various attachments were also performed using WRC107. Code calculations and structural analysis were also performed on a silo sitting on the purge head by three support legs.

 

The components that were outside the scope of ASME Section VIII, Division 1, were evaluated using Finite Element Analysis (FEA). Two FEAs were performed:

  • Finite Element Model (FEM) was generated to analyze clamped body flanges using (10) independent clamps. An internal pressure of 150 psig was used in the analysis of the clamps and the body flanges. This analysis was performed using brick elements.